Infineon AURIX: Automatic trace configuration fails

01-Aug-2024

When using Automatic Trace configuration (i.e., when Manual Trigger Configuration is not selected) and starting the recording, the Analyzer may show a warning:

Cannot configure: There are no hardware resources to configure all of the requested areas. 

The Analyzer attempts to use one POB (Processor Observation Block) for each core. When there are more CPU cores than POBs, this is not possible and results in the above error.



Possible solution

Perform a Manual Trace Configuration


More resources in winIDEA Help

Was this answer helpful?