Arm Cortex-M Cypress Traveo II 2M VIRGIN devices: Fail to establish debug session

01-Aug-2024

Debug session with Cypress Traveo II VIRGIN (life cycle) devices will be established partially - the core will not be stopped at the start of your application.


Debugging VIRGIN devices is not supported from winIDEA 9.21.29. To inspect if you have a VIRGIN device refer to topic Reset and Flash programming fails.


Possible solution

1. Open Hardware | CPU Options | CoreN.

2. Set option Preset PC after stopped in init to Preset to Entry Point. 


More resources in winIDEA Help